ASTM A967/A967M-13 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts.
بیشترAbstractThis specification covers several different types of chemical passivation treatments for stainless steel parts. The treatments are the following: immersion treatment using nitric acid solutions, immersion treatment using citric acid solution, and
بیشترASTM A967, 2005 Edition, September 1, 2005 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
بیشترASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. Language (s): English. Published date: 07-01-2017. Publisher: American Society for Testing and Materials.
بیشترASTM B600 [affil link] is the proper standard for cleaning and descaling titanium alloys. Toby Padfield Automotive module supplier - Michigan 2005. A. ASTM A967 [affil link] is often specified for passivation of titanium, although it is a misnomer for sure. What you are removing by "passivation" of titanium is any iron or iron oxide that may ...
بیشترStandard Guide for Descaling and Cleaning Titanium and Titanium Alloy Surfaces. Buy ASTM A 967 A967M 2017 chemical passivation treatments for stainless …
بیشترASTM A967/A967M – Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. This standard details effective methods to …
بیشتر1.1 This practice covers recommendations and precautions for cleaning, descaling, and passivating of new stainless steel parts, assemblies, equipment, and installed systems. These recommendations are presented as procedures for guidance when it is recognized that for a particular service it is desired to remove surface contaminants that …
بیشترASTM A967 and ASTM A380 – two of the most widely recognized industry standards for passivation – list a number of methods that can be used to passivate a part; however, they do not claim to be all-encompassing. ASTM recognizes that there are many valid ways to passivate a stainless steel part.
بیشترAttention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU.
بیشترThe ASTM A967/A967-13 replaces ASTM A967/A967M-05 which is now obsolete. Keywords. cleaning of stainless steel; passivation; passivation tests; tests for cleanliness of stainless steels;; ICS Number Code 77.140.20 (Steels of high quality) To find similar documents by ASTM Volume: 01.03 (Steel--Plate, Sheet, Strip, Wire; Stainless Steel Bar)
بیشترThe ASTM A967 passivation standard applies to the cleaning, passivation and testing of stainless steel parts. Chemical passivation removes free iron and other surface contaminants from stainless steel parts, improving corrosion resistance. Stainless steel passivation performed to the ASTM A967 standards meets these standards by passing …
بیشترFull Description. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of ...
بیشترMaterials used in this investigation were SS 304, 15-5PH, and 17-4PH whose chemical composition was determined by X-ray fluorescence. Preparation of the electrodes: each of the SS was prepared according to ASTM A380 [] in order to obtain a surface without harshness, after which a washing and rinsing was carried out to eliminate preparation …
بیشترASTM A967 Chemical Passivation Treatment for Stainless Steel. This covers several different types of chemical passivation treatment for stainless steel parts. The treatments …
بیشترthe ASTM website. 3 Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. 4 In accordance with QQ-P-35C Notice 3, …
بیشترOne is a commercially available citric acid passivation solution that contains citric acid and cleaning compounds and meets ASTM A 967 (Citric 4), and the other two passivation solutions are Type II and Type VII from AMS-QQ-P-35. These AMS-QQ-P-35 solutions are used by the aerospace industry to passivate stainless steel parts.
بیشترASTM does not guarantee access, and will not be liable for damages or refunds if the Product becomes unavailable temporarily, or if access becomes slow or incomplete due to system back-up procedures, Internet traffic volume, upgrades, overload of requests to servers, general network failures or delays, or any other cause that may from …
بیشترA967 was developed for replacement of Mil QQ-P 35. As part of the development, the word "dissolved" appears to be accidental dropped in para. 7.2. for the description of clean water. ... ASTM offers descriptions of work items in the interest of openness, as well as to solicit input from interested stakeholders who may not be …
بیشترA summary of the various nitric acid passivation methods per ASTM A967 is provided below: • Nitric 1: 20-25 v% Nitric Acid, 2.5 w% Sodium Dichromate, 120-130F, 20 Mins minimum • Nitric 2: 20-45 v% Nitric Acid, 70-90F, 30 Mins minimum • Nitric 3: 20-25 v% Nitric Acid, 120-140F, 20 Mins minimum
بیشتر1. Passivation Process: ASTM A967 defines the passivation process as the removal of free iron or other foreign matter from the surface of stainless steel by means of a chemical treatment. This treatment encourages the formation of a passive oxide layer, strengthening the steel's resistance to corrosion. 2.
بیشترScope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and …
بیشترASTM A967 - Specification for Chemical Passivation Treatments for Stainless Steel Parts (based on US Defense Department standard QQ-P …
بیشترTitle: Chemical Passivation Treatments for Stainless Steel Parts (Replaced by ASTM-A967/A967M) Scope: This specification covers several different types of …
بیشترTitle: Chemical Passivation Treatments for Stainless Steel Parts (Replaced by ASTM-A967/A967M) Scope: This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. Status:
بیشترAMS 2700 has no guidelines for descaling or chemical cleaning processes detailed in ASTM A380 and ASTM A967; AMS 2700 is strictly a specification on passivation processes. ASTM A967 describes a passivation procedure must follow cleaning and / or descaling. Any contamination not removed prior to passivation reduces a part's corrosion ...
بیشترRevision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...
بیشترASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems ... ASTM A967/A967M-13; Included in Packages.
بیشترBoth nitric acid and citric acid are effective in passivating many grades of stainless steel, and both methods are described in detail in the industry standards ASTM A967 and AMS 2700. In the 1960s, the U.S. military defined the first specifications for passivation using nitric acid on stainless steel in the QQ-P-35 standard. Over time, however ...
بیشترASTM A967/A967M-17. July 1, 2017. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types …
بیشتر5.3 This test method is particularly useful for electrical steels coated with inorganic insulating coatings having surface insulation resistivities in excess of 0.3 kΩ·cm 2 [30 kΩ·mm 2] when tested using Test Method A717/A717M (a Franklin current less than 0.02 A). This test method can readily be extended to any range of insulation resistivity …
بیشترASTM A967/A967M, 2017 Edition, July 1, 2017 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
بیشترASTM A967 - Specification for Chemical Passivation Treatments for Stainless Steel Parts (based on US Defense Department standard QQ-P-35C) 3. BS EN 2516 - Passivation of Corrosion Resisting Steels and Decontamination of Nickel Base Alloys ASTM A380 nitric acid based passivation treatments
بیشتر